EFRON is the platform of CASE Real Estate for technical real estate analysis.

0documents in the data room.
Five of them concern the boiler room.
  1. Two gas boilers, 325 kW each, built 2001 SupplyInspection reports of 29 Nov 2016 · p. 1 and 2
  2. Flow temperature 70 °C SupplyInspection report boiler 1 · p. 1
  3. Last maintenance on 4 Sep 2017 Maintenance & inspectionMaintenance report 2017 · p. 1
  4. Energy certificate valid until 9 Nov 2025 Thermal insulationEnergy certificate · p. 1
  5. Heat consumption 114.5 kWh/m² per year Thermal insulationEnergy certificate · p. 3
  6. Boiler 2: “no defects” ticked, “defective” in the remarks field. Measurements missing. Finding · contradictionQuestion to the seller
  7. Maintenance not evidenced since 2017. Energy certificate expired. Finding · documents missing4,846 documents searched
Chimney inspection report for boiler 1, anonymised
Maintenance report for the heating system from 2017, anonymised
Energy performance certificate, page 1, anonymised
Energy performance certificate, page 3 with recorded consumption
Chimney inspection report for boiler 2, anonymised
Boiler 1 · Inspection report of 29 Nov 2016 measured, in order
Boiler 2 · Inspection report of 29 Nov 2016 ticked: no defects · remark: defective
KG 420 · Replace boilers · Phase II
€0
End of service life reached in 2021
CRREM · Carbon stranding
2028→2035
Year from which the building exceeds the target pathway
Recommendation · heat pump with gas peak load, LED
€1,504,000
4th fl.3rd fl.2nd fl.1st fl.GFBasement KG 360 Roof KG 330 Walls KG 420 Heating KG 430 Ventilation KG 460 Lift checked on site Flow 70 °C? check heating curve
Building section · demo property
Carbon intensity in kg CO₂e/m² per year 0204060 2020202520302035204020452050 CRREM target pathway 1.5 °C Status quo Stranding 2028 Stranding 2035 Heat pump 2027
Carbon pathway to CRREM · office building, demo property · indicative
Checked · CASE Real Estate
Site visit photo of the boiler room with two gas boilers
Boiler room, site visit
EFRONThe engineer
reads.sorts.cites.computes.inspects.judges.signs off.
01 / 07
What EFRON is

EFRON turns a data room into a verified data basis. Everything else follows from it.

Input
  • Data roomPDFs, scans, spreadsheets, e-mails, handwriting
  • Site visit photos
  • Q&A
  • Location data from public sourcesFlooding, earthquakes, mining
  • Consultant's notes

Verified data basisEvery statement names its document and page. Every figure is calculated by fixed rules.

Output
  • ReportsShort, full and red-flag report, fact sheets
  • Follow-up questionsQ&A
  • List of missing documents
  • CapEx registerover ten years
  • Maintenance and inspection calendar
  • Energy, CRREM, EU Taxonomy
  • Client portal and data export

EFRON is AI-assisted and in daily use at CASE. Clients receive verified results and access to the client portal.

Client portal

The client reads along.
Down to the original page.

The client portal shows the current status instead of a PDF. One click on the source opens the original document next to the extracted finding.

platform.efron.io/portal
Property overview in the EFRON client portal with cover photo, key figures and results, demo property
Click on the source
Digital TwinInspection report boiler 2.pdf Page 2
Original
Extracted

The chimney inspection report of 29 Nov 2016 concerns the boiler in the basement. The remarks field states the boiler is defective. At the same time “No defects found” is ticked. No measurements are filled in.

Class
Boiler
Inspection step
Supply
Location
Page 2 of 2
Comparison view in the client portal · demo property
In the portal
  • Property overview
  • TDD report
  • Digital twin
  • CapEx
  • Maintenance calendar
  • Building anatomy
  • Documents
  • Photos
  • Document check
  • Q&A
  • CRREM
  • EU Taxonomy
  • Property comparison
  • Chat

The consultant controls what is released.

One data basis, many analyses

One building. Six ways of looking at it.

All analyses draw on the same verified data. When a document changes, EFRON shows which results need recalculating.

4th fl.3rd fl.2nd fl.1st fl.GFBasement KG 360 Roof KG 330 Walls KG 420 Heating KG 430 Ventilation KG 460 Lift
Building model · demo property · drag to rotate

Building anatomy

Components and systems, ordered by DIN 276 cost group. With inspections, maintenance, defects, remaining service life and the basis for the maintenance calendar.

57
component groups
16
inspections overdue

In a portfolio, properties can be compared directly in every analysis.

After the report

The report is a by-product.

New documents

If the seller submits something later, EFRON shows which results are outdated and recalculates them selectively. What the consultant has decided stays protected.

Data for your systems

The verified data can be transferred to ERP, CAFM, ESG reporting and asset management systems, as JSON or via client-specific interfaces.

  • Component and system data
  • CapEx and maintenance
  • ESG and regulation
  • Maintenance and inspection data
  • Building master data
  • Photo documentation

Ready for sale

The data basis is kept up to date during the holding period. On a sale, it produces a TDD report again, signed and with liability.

export.json · one record from the demo property
{
  "property": "Demo property",
  "component": "Boiler",
  "cost_group": "KG 420",
  "year_built": 2001,
  "measure": "replace",
  "phase": "II",
  "cost_net_eur": 168000,
  "source": "Inspection report boiler 1, p. 1"
}
EFRON
  • reads every file in the data room
  • backs every statement with document and page
  • works through every technical discipline to a fixed scheme
  • calculates costs, energy demand, carbon pathway and remaining service life by fixed rules
  • shows what needs recalculating when new documents arrive
The engineer
  • inspects the property on site
  • checks statements against the document and on site
  • resolves contradictions and decides
  • signs off the result
  • carries the results into the purchase agreement, valuation and business plan

Technical control and liability remain with CASE.

Checked · CASE Real Estate
With EFRON we produce auditable results and data. Our quality standard remains the same as in every one of our advisory mandates.
Claudio Calandri · Technical Managing Director, CASE Real Estate
Frequently asked questions

“Couldn't you just do this with ChatGPT?”

A language model summarises individual documents well. A technical inspection demands more: the entire data room must be captured completely, findings from the site visit must be included and every statement must be traceable. To do this, EFRON works through every technical discipline to a fixed scheme developed over ten years of technical consulting at CASE. All calculations are reproducibly defined and proven in practice. At the end an engineer checks the result, and CASE is liable for it.

“Every software spots missing documents these days.”

Many tools compare the files in a data room against a fixed list. Which evidence a building actually requires, however, only follows from its systems, its use and the findings of the site visit. EFRON checks whether this evidence is present in substance, complete and up to date. What matters for the transaction is weighted by the experience of CASE engineers. The result is a list of missing documents ranked by relevance, neither generic nor petty.

“I can get CapEx, energy and CRREM from a SaaS tool.”

Most of these tools work with benchmarks: from a few details about a building they estimate costs and consumption based on similar properties. EFRON works on the individual property. The data comes from its documents and the site visit, is backed at component level and technically checked, and all analyses run on the same basis. Behind it are the engineers of CASE and testing on real projects. The verified data can be exported to such systems.

Track record

Grown out of practice.

First came the consulting, then the technical framework, then the technology.

  1. 2016

    CASE is founded

    Technical real estate consulting for institutional clients. The inspection steps EFRON follows today come from this work.

  2. 2025

    Development begins

    Ten years of consulting practice are translated into a technical framework. EFRON runs alongside real projects for months.

  3. Early 2026

    In use

    Released once the results held up in day-to-day work. The CASE team has used it daily since.

  4. May 2026

    ZIA Innovation Radar

    Included in the ZIA Innovation Radar 2026.

    ZIA Innovation 2026 seal
  5. Summer 2026

    Energy module and client portal

    The in-house energy calculation engine has been technically approved. Clients see their results in the portal, down to the source.

Calculated and checked according to
  • DIN 276
  • DIN/TS 18599
  • GModG, formerly GEG
  • CRREM
  • EU Taxonomy
CASE Real Estate

The consultancy behind EFRON.

CASE Real Estate is a technical and commercial real estate consultancy based in Stuttgart. Since 2016 CASE has supported institutional clients from acquisition due diligence to project development.

> 2,000
properties assessed
> €12bn
transaction volume supported
> 8m m²
floor area inspected
10 years
real estate consulting
Selected clients of CASE

Domicil · HIH Invest · Industria · Patrizia · PFA Pension · Swiss Life · Union Investment

Data security
  • GDPR-compliant
  • Project data is not used to train AI models
  • Data processing agreements are in place with all external service providers
  • Data of different clients is strictly separated